BD series AC Current Transducer
● Model: BD-AI / BD-AI2
● AC current input: 0-1A or 0-5A
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BA Series Split Current Transducer
● Model: BA20(II)-AI,BA50(II)AI
● Aperture: 20mm,50mm
● Input: AC0-600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA Series Intelligent Current Sensor
● Model: BA20(II)-AI,BA50(II)AI
● Aperture: 20mm,50mm
● Input: AC0-600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BD 3 Phase Voltage Transducer
● Model:BD-3V3 / BD-4V3
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD-3P/4P 3 Phase Active Power Transducer
● Model: BD-3P/BD-4P
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
BA20-AI AC Current Transducer Measuring 0-200A
● Model: BA20-AI/I, BA20-AI/V
● Aperture: 20mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA10-AI AC Current Transducer Measuring 0-50A
● Model: BA10-AI/I, BA10-AI/V
● Aperture: 9.5mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA Series AC Straight Through Current Transducer
● Model: BA05,BA10,BA20,BA50
● Aperture: 5mm,10mm,20mm,50mm
● Input: AC0-10A,AC0-50A,AC0-200A,AC0600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA50-AI AC Current Transducer Measuring 0-600A
● Model: BA50-AI/I, BA50-AI/V
● Aperture: 50mm
● Input: AC0-(60-600)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BD-AV Single Phase AC Voltage Transducer
● Model:BD-AV
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD series Electrical Power/Energy Transducer
● Model: BD-3E/BD-4E
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
AKH-0.66/I series current transformer
● Current transformer for measurement
● Suitable for cables or copper bus
● Used with energy meters or relays
Standards
IEC/EN61869-1, IEC/EN61869-2 -
BA50L AC Leakage Current Transducer
● Model: BA50L-AI/I, BA50L-AI/V
● Input: AC0-1A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V