ADL3000-E(DTSD1352) series of smart meters were designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides various data on previous 12 months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to MODBUS-RTU. ADL3000-E can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electricity power meter in the IEC62053-21, IEC62053-22 standards.
① Seal for Anti theft ② Brand ③ Panel ④ Enter-wire
⑤ Auxiliary function ⑥ Pulse output light ⑦ Button ⑧ Outlet wire
ADL3000(DTSD1352) meters can be used for Sungrow inverters SG30CX, SG50CX, SG110CX, and Ginlong/Goodwe/Growatt/Sunways inverters, etc.
For export control and load consumption, an energy meter (DTSD1352-C/1(6)A with external CT) needed to be connected.
All of the components are connected via daisy-chain RS485 as per standard RS485 topology..
Used as a general 3 phase electricity meters
● 3 phase 3 wires, 3 phase 4 wires
● Rated voltage: AC 3×100V, 3×380V, 3×57.7/100V, 3×220/380V;
● Rated current: 3×1(6)A, or 3×10(100)A
● Accuracy: 0.5S
● Communication: 2 channels of RS485(Modbus-RTU)(Optional), Infrared communication
Electricity Data Measurement
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● A, B, C phase positive active kWh
● 2~31ST Voltage and current harmonic(optional)
● Multi tariff: Adapt 4 time zones, 2 time interval lists,
14 time interval by day and 4 tariff rates(optional)
● Max demanded kWh and time happened(optional)
● Temperature measurement: Support 3 outlay NTC temperature(optional)
● 1 DI/1 DO(optional)
● Frozen data on last 48 months, last 90 days(optional)
● Pulse output: active pulse output, reactive pulse output, clock pulse output
● Key programming: 3 keys to communication and set parameters
● Standard&Certificate: CE; IEC
● Display: 8 digits display U, I, P, Q, PF, kWh and other energy consumption
● Frequency: 45-65Hz
● Mounted: DIN 35mm
● Pulse constant: 400imp/kWh, 6400imp/kWh
● Starting current: Direct connect: 0.004Ib
● Connect via CT: 0.001ln
● Baud rate: 1200bps~19200bps
● Clock: ≤0.5s/d
Connect via CTs
Direct connect
3 phase 4 lines connect via CT
3 phase 4 lines direct connect
3 phase 3 lines connect via CT
3 phase 3 lines direct connect
Q: What’s the difference of current input via direct connect or via CTs?
A: Normally, for 3-phase loads with rated current below 80A AC, we will use model of ADL400 whose current input is via direct connect. Specs of “Rated Current: 10(80)A AC” was aimed for this model of ADL3000(DTSD1352) (current input via direct connect). 10 means basic current is 10A AC, 80 means rated current input is 80A AC, its measuring range is 0.01A-80A.
And for 3-phase loads with rated current over 80A AC, we will use model of ADL3000(DTSD1352) whose current input is via CTs (usually paired with -/5A CTs whose secondary current output is with 5A AC rated current output). Specs of “Rated Current: 1(6)A AC” was aimed for this model of ADL3000(DTSD1352) (current input via CTs). 1 means basic current is 1A AC, 6 means max current input is 6A AC.
Q: Do your company also have paired CTs for ADL3000(DTSD1352)?
A: Usually, we will recommend our user to use split-core CTs called AKH-0.66/K K-φ Series or solid-core CTs called AKH-0.66/I Series to the paired with ADL400 (current input via CTs)
Q: How can I set the CT or PT ratio of ADL3000(DTSD1352)?
A: Current ratio of ADL3000(DTSD1352) could be set by using the keypads on ADL3000(DTSD1352) and following the instruction of ADL3000(DTSD1352) manual. Also, setting need to be according to the CTs or PTs ratio which were paired with ADL3000(DTSD1352). For example, if the current input is via 250A/5A CTs, the CT ratio on ADL3000(DTSD1352) should be set to 250/5=50. And if the voltage input is via direct connect, PT ratio on ADL3000(DTSD1352) should be set to 1. When the problem hasn’t been solved, please contact us for help.
Q: Could ADL3000(DTSD1352) be used in IoT Energy Monitoring System for factory or building?
A: ADL3000(DTSD1352) has standard RS485 interface and MODBUS-RTU communication protocol which allow it to be integrate with our IoT Energy Monitor Solution that can enable our users to remotely check all the data collect by energy meters like ADL3000(DTSD1352) on their mobile phone or PC. For more information, please Contact us or check in IoT Energy Monitoring Solution Introduction.
Q: What is Multi-rate/tariff function? How does it work?
A: First,multi-rate/tariff function was designed to be used for billing system. Second, the electricity price of different time duration in a day is different in some country.
Energy meter with this function can measure the kwh data and assign them to several time duration in a day and put a label of spike/peak/flat/valley kwh on them respectively. And if such energy meter was connected to the billing system by using a IoT gateway, it can send the kwh data of different time duration which was with the label of spike/peak/flat/valley kwh to the billing system for calculating the electricity bill of different time duration in a day.
For example, the electricity price of spike kwh is 5 USD/1 kwh, and time duration of from 9:00 am to 11:30 am was labeled as spike kwh.
Then, if energy meter record 3 kwh used in total during 9:00 am to 11:30 am, it will send the data of 3 kwh with the label of spike kwh to the billing system, and the system calculate the electricity cost of 3x5=15USD in total from 9:00 am to 11:30 am.
Other Question? Please contact us and we will get back to you as soon as possible.
IOT Platform
All electricity data can be transmitted to the IOT platform
Prepayment management
Electricity data analysis
Alarming
Issue report
ADL200/C Single Phase Meter
RS485(Modbus-RTU)
Multi-tariff
3 months historical energy data frozen storage
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADW200 Series
Multi-channel Energy Meter
5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
ADL3000-E/C(DTSD1352-C) 3 Phase Meter
RS485(Modbus-RTU)
2 channels of RS485
Multi-tariff
1DI/1DO
3 channels of temperature measurement
2-31st harmonic
Frozen data on last 48 months, last 90 days
ADW210 Series
Multi-channel Energy Meter
Input current: 5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
AMC72 3 Phase Energy Meter
Input current: 5A, or 1A
RS485(Modbus-RTU)
2DI/2DO
THDi, THDu
SOE:event record
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADF400L Series
Multi-channel Energy Meter
Measure 12 channels of 3 phase circuits,
or 36 channels of 36 single phase circuits
Input current: 3*1(6)A, 80A
APM830 Three Phase Energy Meter
Measurement: total electrical measurement,
Pulse output of energy
Demand data, Event log
Extreme value statistics
Power quality analysis
RS485(Modbus-RTU), 1 Profibus-DP
10DI+4DO, 8AI+4AO
Multi tariff, TF card storage
1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
Specification
|
3 phase 3 wires, 3 phase 4 wires
|
|
Voltage
|
Reference voltage
|
3×100V、 3×380V、3×57.7/100V、 3×220/380V
|
Consumption
|
<10VA(Single phase)
|
|
Impedance
|
>2MΩ
|
|
Accuracy class
|
Error±0.2%
|
|
Current
|
Input current
|
3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer)
|
Consumption
|
<1VA(Single phase rated current)
|
|
Accuracy class
|
Error±0.2%
|
|
Power
|
Active, reactive, apparent power, error±0.5℅
|
|
Frequency
|
45~65Hz, Error±0.2%
|
|
Temperature
|
-40℃~99℃
|
|
Energy
|
Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2)
|
|
Clock
|
≤0.5s/d
|
|
Energy pulse output
|
1 active optocoupler output, 1 reactive optocoupler output
|
|
Switching output
|
1 Switching output, Maximum allowed voltage: DC/AC 220V
|
|
Switching input
|
1 optocoupler input,Maximum allowed voltage: DC/AC 220V
|
|
Width of pulse
|
80±20ms
|
|
Pulse constant
|
6400imp/kWh,400imp/kWh(Correspond with the basic current)
|
|
Interface and communication
|
RS485:Modbus RTU
|
|
Range of communication address
|
Modbus RTU:1~ 247;
|
|
Baud rate
|
1200bps~19200bps
|
|
Relative temperature
|
-25℃~+55℃
|
|
Relative humidity
|
≤95℅(No condensation)
|
1. who are we?
We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc.
Our Products: AC/DC electricity meters, current transformers, hall sensors, transducers, gateways, Motor protectors, wireless temperature monitoring, residual current relays, medical IT, IOT platform, other energy management systems, etc.
As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.
2. What is your website?
www.acrel.sg
3. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
4.what can you buy from us?
AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.
5. why should you buy from us not from other suppliers?
147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.
6. what services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc.
Accepted Payment Currency: USD, EUR, RMB, etc.
Accepted Payment Type: T/T, L/C, etc.
Language Spoken:English, Spanish, Chinese, etc.