ADL series DIN-rail mounted multifunctional electric energy meter is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc.
The product has the advantages of high precision, small volume, high respondent speed and convenient installation. The product has the features of sampling, metering and monitoring power parameters, communicating with an inverter or an energy management system (EMS), realizing the functions of preventing reverse flow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional metering and household distributed photovoltaic energy management.
Function |
Descriptions |
ADL200N-CT |
ADL400N-CT |
Electric energy metering |
Active energy metering (forward and reverse) |
■ |
■ |
Reactive energy metering (forward and reverse) |
■ |
■ |
|
Split-phase energy |
□ |
■ |
|
Electric quantity measurement |
U, I |
■ |
■ |
P, Q, S, PF, F |
■ |
■ |
|
LCD display |
Segmented LCD display |
■ |
■ |
Key programming |
ommunication, transformation ratio and other parameters can be programmable by the key |
□ |
■ |
Pulse output |
Active pulse output |
■ |
■ |
LED alarm |
Operation instructions |
□ |
■ |
Communication |
RS485:Modbus RTU |
■ |
■ |
Item |
Performance Parameters |
|||
Model Series |
ADL200N-CT | ADL400N-CT | ||
Measurement |
Grid |
Single-phase | Three-phase four-wire, three-phase three-wire, single-phase three-wire | |
Voltage |
Rated voltage |
230V | 3×220/380V、3×230/400V、3×277/480V | |
Input Range |
±20% | |||
Overload |
1.2 times rating (continuous) ,2 times the rating for 1 second | |||
Power consumption |
<0.2VA | |||
Accuracy class |
Error ±0.5% | |||
Current |
Input current |
80A, 120A, 200A, 300A | 3×80A, 3×120A, 3×200A, 3×300A | |
Overload |
1.2 times rating (continuous) ,2 times the rating for 1 second | |||
Power consumption |
<0.2VA | |||
Accuracy class |
Error ±0.5% | |||
Power |
Active, reactive, apparent power, error ±0.5℅ | |||
Grid frequency |
45~65Hz, error ±0.5% | |||
Response rate |
≤100ms (voltage, current, power) | |||
≤1s (electrical energy) | ||||
Metering |
Electric energy |
Active energy :Class B (split current transformer)Reactive energy (Class 2 accuracy) | ||
electromagnetic compatibility |
Electrostatic discharge immunity class III | |||
Electrical fast transient burst immunity class IV | ||||
Surge (shock) immunity Class IV | ||||
Security |
Power frequency withstand voltage |
Between communication and signal input, AC4kV 1min | ||
Insulation resistance |
Input and output terminals to casing >100MΩ | |||
Communication |
Interface and communication protocol |
RS485 interface and Modbus RTU protocol | ||
Communication address range |
Modbus RTU:1~ 247; | |||
Baud rate |
Support 1200bps-38400bps | |||
Environment |
Operating temperature |
-40℃~+70℃ | ||
Storage temperature |
-40℃~+70℃ | |||
Relative humidity |
≤95℅ (without condensation) | |||
Altitude |
≤3000m |
Supporting transformer specifications
Ordering specifications | Current transformer parameters | Number of transformers |
ADL400N-CT/D10 | 80A/26.6mA | 3 |
ADL400N-CT/D16 | 120A/40mA | 3 |
ADL400N-CT/D24 | 200A/66.6mA | 3 |
ADL400N-CT/D36 | 300A/100mA | 3 |
Three-phase Four-wire Connection Through Current Transformer
Three-phase Three-wire Connection Through Current Transformer (this connection method is limited to three-phase balance) (instrument is set as 3P4L)
ADL400N-CT Three-phase Three-wire Connection Through Current Transformer (instrument is set as 3P3L)
ADL400N-CT Single-phase Three-wire Connection Through Current Transformer
Q: What’s the difference of current input via direct connect or via CTs?
A: Normally, for 3-phase loads with rated current below 80A AC, we will use model of ADL400 whose current input is via direct connect. Specs of “Rated Current: 10(80)A AC” was aimed for this model of ADL400 (current input via direct connect). 10 means basic current is 10A AC, 80 means rated current input is 80A AC.
And for 3-phase loads with rated current over 80A AC, we will use model of ADL400 whose current input is via CTs (usually paired with -/5A CTs whose secondary current output is with 5A AC rated current output). Specs of “Rated Current: 1(6)A AC” was aimed for this model of ADL400 (current input via CTs). 1 means basic current is 1A AC, 6 means max current input is 6A AC.
Q: Do your company also have paired CTs for ADL400?
A: Usually, we will recommend our user to use split-core CTs called AKH-0.66/K K-φ Series or solid-core CTs called AKH-0.66/I Series to the paired with ADL400 (current input via CTs)
Q: How can I set the CT or PT ratio of ADL400?
A: Current ratio of ADL400 could be set by using the keypads on ADL400 and following the instruction of ADL400 manual. Also, setting need to be according to the CTs or PTs ratio which were paired with ADL400. For example, if the current input is via 250A/5A CTs, the CT ratio on ADL400 should be set to 250/5=50. And if the voltage input is via direct connect, PT ratio on ADL400 should be set to 1. When the problem hasn’t been solved, please contact us for help.
Q: Could ADL400 be used in IoT Energy Monitoring System for factory or building?
A: ADL400 has standard RS485 interface and MODBUS-RTU communication protocol which allow it to be integrate with our IoT Energy Monitor Solution that can enable our users to remotely check all the data collect by energy meters like ADL400 on their mobile phone or PC. For more information, please Contact us or check in IoT Energy Monitoring Solution Introduction.
Q: What is Multi-rate/tariff function? How does it work?
A: First,multi-rate/tariff function was designed to be used for billing system. Second, the electricity price of different time duration in a day is different in some country.
Energy meter with this function can measure the kwh data and assign them to several time duration in a day and put a label of spike/peak/flat/valley kwh on them respectively. And if such energy meter was connected to the billing system by using a IoT gateway, it can send the kwh data of different time duration which was with the label of spike/peak/flat/valley kwh to the billing system for calculating the electricity bill of different time duration in a day.
For example, the electricity price of spike kwh is 5 USD/1 kwh, and time duration of from 9:00 am to 11:30 am was labeled as spike kwh.
Then, if energy meter record 3 kwh used in total during 9:00 am to 11:30 am, it will send the data of 3 kwh with the label of spike kwh to the billing system, and the system calculate the electricity cost of 3x5=15USD in total from 9:00 am to 11:30 am.
Other Question? Please contact us and we will get back to you as soon as possible.
IOT Platform
All electricity data can be transmitted to the IOT platform
Prepayment management
Electricity data analysis
Alarming
Issue report
ADL200/C Single Phase Meter
RS485(Modbus-RTU)
Multi-tariff
3 months historical energy data frozen storage
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADW200 Series
Multi-channel Energy Meter
5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
ADL3000-E/C(DTSD1352-C) 3 Phase Meter
RS485(Modbus-RTU)
2 channels of RS485
Multi-tariff
1DI/1DO
3 channels of temperature measurement
2-31st harmonic
Frozen data on last 48 months, last 90 days
ADW210 Series
Multi-channel Energy Meter
Input current: 5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
AMC72 3 Phase Energy Meter
Input current: 5A, or 1A
RS485(Modbus-RTU)
2DI/2DO
THDi, THDu
SOE:event record
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADF400L Series
Multi-channel Energy Meter
Measure 12 channels of 3 phase circuits,
or 36 channels of 36 single phase circuits
Input current: 3*1(6)A, 80A
APM830 Three Phase Energy Meter
Measurement: total electrical measurement,
Pulse output of energy
Demand data, Event log
Extreme value statistics
Power quality analysis
RS485(Modbus-RTU), 1 Profibus-DP
10DI+4DO, 8AI+4AO
Multi tariff, TF card storage
1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
Specification
|
3 phase 3 wires, 3 phase 4 wires
|
|
Voltage
|
Reference voltage
|
3×100V、 3×380V、3×57.7/100V、 3×220/380V
|
Consumption
|
<10VA(Single phase)
|
|
Impedance
|
>2MΩ
|
|
Accuracy class
|
Error±0.2%
|
|
Current
|
Input current
|
3×1(6)A,3×10(80)A
|
Consumption
|
<1VA(Single phase rated current)
|
|
Accuracy class
|
Error±0.2%
|
|
Power
|
Active, reactive, apparent power, error±0.5℅
|
|
Frequency
|
45~65Hz, Error±0.2%
|
|
Energy
|
Active energy(Accuracy class:0.5), reactive energy(Accuracy class 2)
|
|
Clock
|
≤0.5s/d
|
|
Energy pulse output
|
1 active optocoupler output
|
|
Width of pulse
|
80±20ms
|
|
Pulse constant
|
400imp/kWh,10000imp/kWh(Correspond with the basic current)
|
|
Interface and communication
|
RS485:Modbus-RTU
|
|
Range of communication address
|
Modbus RTU:1~ 247; |
|
Baud rate
|
1200bps~19200bps
|
|
Relative temperature
|
-25℃~+55℃
|
|
Relative humidity
|
≤95℅(No condensation)
|
1. who are we?
We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc.
Our Products: AC/DC electricity meters, current transformers, hall sensors, transducers, gateways, Motor protectors, wireless temperature monitoring, residual current relays, medical IT, IOT platform, other energy management systems, etc.
As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.
2. What is your website?
www.acrel.sg
3. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
4.what can you buy from us?
AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.
5. why should you buy from us not from other suppliers?
147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.
6. what services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc.
Accepted Payment Currency: USD, EUR, RMB, etc.
Accepted Payment Type: T/T, L/C, etc.
Language Spoken:English, Spanish, Chinese, etc.