AIM-M100 Digital Remote Indicators for line isolation mornitoring
General
AID Series alarm and display device is remote display and sound and light alarm device by using advanced fieldbus communications technology .AID Series alarm and display device have four models : AID10,AID120, AID150 and AID200 ,Products are Classified according to the installation method and display.The device can be installed on the operating room or information control panel of intensive care unit , the medical staff can easily know the status of medical isolated power systems, and the type of fault when the system fails.
Function
* Can read and display monitoring data and alarm information of insulation monitor in real-time by bus communication
* Can set the alarm parameters of insulation monitor remotely
* When the system fails,products can generate sound and light alarm,if you press the mute button,the sound can be turned off,but the corresponding fault indicator does not go out until the fault is removed so far
Specification
Model Parameter |
AID10 |
AID120 |
AID150 |
AID200 |
||
Auxiliary power |
Voltage |
DC24V |
||||
Consumption |
<0.6W |
|||||
Insulation resistance Measurement range |
-- |
0-999KΩ |
-- |
-- |
||
Insulation alarm value range |
-- |
50-999KΩ |
-- |
-- |
||
Transformer load rate display |
-- |
Percentage display |
-- |
-- |
||
Load current alarm value settings |
-- |
14A,18A,22A,28A,35A,45A |
||||
Temperature alarm value range |
-- |
0-+200℃ |
||||
Alarm |
Sound and light alarm |
|||||
Alarm type |
Insulation fault,overload,over-temperature,equipment failure |
|||||
Communication |
RS485 interface,Modbus-RTU protocol |
|||||
Display |
-- |
LED display |
LCD display |
LCD display |
Application video
https://youtu.be/FC-17bv8F34
Dimension
Quotation
Model |
Function |
FOB Shanghai(USD) |
Wholesale price |
AID10 |
Monitor one AIM-M10,suitable for embedded cabinet installation |
61.6 |
Please contact us in detail. We can offer you the best price. |
AID120 |
Monitor one AIM-M100,embedded in the wall installation |
92.4 |
|
AID150 |
Monitor 1~16 M10M100, AID150 can also monitor AIM-R100 |
92.4 |
|
AID200 |
monitor 1~16 M200 data |
92.4 |
Projects
1. Acrel Medical Isolated Power Supply System in Luanda General Hospital, Angola
2. ACREL Hospital Isolated Power Supply Application in Malaysia
Acrel Medical IT System Insulation Monitoring and Fault Location Products Selection Table V1.0
Note:“□”is optional,“—”is not optional,“■”is selection.
Medical Single Phase Isolation Transformer |
AITR-3150 |
AITR-5000 |
AITR-6300 |
AITR-8000 |
AITR-10000 |
Capacity |
3150VA |
5000VA |
6300VA |
8000VA |
10000VA |
|
□ |
□ |
□ |
□ |
□ |
Insulation monitor |
AIM-M10 |
AIM-M100 |
AIM-M200 |
|
|
Power supply |
|||||
AC220±10% |
|
□ |
|
|
|
AC85~265V DC100-300V |
□ |
|
|
|
|
DC24V |
|
|
□ |
|
|
Communication |
|||||
RS485 |
□ |
|
|
|
|
RS485+RS485 |
|
□ |
|
|
|
RS485+CAN |
|
|
□ |
|
|
Output |
|||||
DO1(over temperature) |
□ |
|
|
|
|
DO1(over temperature) DO2(alarm) |
|
|
□ |
|
|
DO1(over temperature) DO2(alarm) DO3(programmable)
|
|
□ |
|
|
|
1 channel DC24V |
□ |
|
|
|
|
Support fault location |
|||||
No |
□ |
□ |
|
|
|
Yes |
|
|
□ |
|
|
Power supply |
ACLP10-24 |
HDR-60-24 |
|
|
|
Insulation monitor |
|||||
AIM-M100 |
□ |
|
|
|
|
AIM-M200 |
|
□ |
|
|
|
Alarm indicator |
AID10 |
AID120 |
AID150 |
AID200 |
|
Display |
|||||
LED |
□ |
□ |
|
|
|
LCD |
|
|
□ |
□ |
|
Multi-machine display |
|||||
No |
□ |
□ |
|
|
|
Yes |
|
|
□ |
□ |
|
|
|||||
Current transformer |
AKH-0.66P26 |
|
|
|
|
|
■ |
|
|
|
|
Test signal generator |
ASG150 |
|
|
|
|
Support fault location |
|
||||
No |
— |
|
|
|
|
Yes |
■ |
|
|
|
|
Fault locator |
AIL150-4 |
AIL150-8 |
|
|
|
Support fault location |
|
||||
No |
— |
— |
|
|
|
Yes |
□ |
□ |
|
|
|
Locate number of channels |
|
||||
<=4 |
□ |
|
|
|
|
>4; <8 |
|
□ |
|
|
|
>8 Note 1 |
□ |
□ |
|
|
|
Other |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. More than 8 channels can be freely combined, and the maximum support 24 locate channels.
Ordering example
Example 1: Isolation transformer 8kVA; AC220V; Insulation monitoring; Operating room LCD display; DO output programmable,According to the selection table,confirm the model is:AITR-8000,AIM-M100,ACLP10-24,AKH-0.66P26,AID150
Example 2:Isolation transformer 10kVA; Insulation monitoring; Fault location; ICU LCD display; DO output;Locate 12 loops;
According to the selection table,confirm the model is:AITR-10000,AIM-M200,HDR-60-24,AKH-0.66P26,AID150,ASG150,AIL150-4,AIL150-8
Q: Are you trading company or manufacturer ?
A: We are a manufacturer in Shanghai,China. Our factory is in Wuxi city, Jiangsu province.
Q: How long is your delivery time?
A: Generally it is 3-5 days if the goods are in stock. Or it is 10-15 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes,we can provide the sample for low price. If you place the order ,all or part of the sample charge will be deducted from the goods.
Q: How long can you send your quotation to us ?
A: After got all the detailed information,we will quote within 1 working days.
Q:What is your terms of payment ?
A: Payment<=1000USD,100% in advance. Payment >1000USD,30% Total contract amount in advance, balance before shipment.
If you have another question,pls feel free to contact us.