DJSF1352-RN DC Energy Meter for Solar Power

● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC


Product Detail

Technical Parameter

FAQ

DC Energy Meter

Measures 2 channels of DC energy and bidirectional DC energy, 2 RS485(Modbus-RTU) , 2DI/2DO, Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V), etc.

Overview

      DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.

      The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power.

 

solar energy meter

Coding Rule

dc kwh meter

      Note: when dual DC input(D)function is selected,if Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided,the built-in power supply of elecctric meter can be used.

Display

solaredge modbus meter

Application

solar energy per square meter
solaredge meter
solaredge consumption meter
solaredge consumption monitoring

 

Other Applications:

Double-gun EV charging piles,
Measures bidirectional energy for storage battery,
DC motors,
DC power generators,
and other DC equipments.

Function

 

● Communication: RS485(Modbus-RTU)
● 2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy

● Voltage input range: DC0-1000V

 

● Input signal: Shunt:0-75mV;

Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.

 

● 2DI/2DO

 

● Accuracy: 1 or 0.5 (connected via shunt)(optional)

 

● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)

 

● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC

 

● Switch input: 2 dry contact inputs

● Pulse output: A second pulse output, an energy pulse output

 

 

● Display: 8 digits display U, I, P, Q, kWh and other energy consumption

 

● Average barrier-free working hours: ≥50000h

 

● Mounted: DIN 35mm

 

solar consumption monitoring

 

 

● Built-in Bipolar Power Source:
Power Supply for Hall Effect CT
Range: DC -12V ~ DC +12V

 

Network

IOT platform

Wiring

solar pv meter

Connected via hall sensor

digital solar power meter

Connected via shunt

Dimension

generation meter for solar pv

Unit: mm

Related Products

AKH-0.66/K-φ24

Split Core

Current Transformer

(150~300)A/5(1)A(333mV)

Hole diameter: 24mm

Read More

IOT Platform

All electricity data can be transmitted to the IOT platform

Prepayment management

Electricity data analysis

Alarming

Issue report

Read More

ADL200/C Single Phase Meter

RS485(Modbus-RTU)

Multi-tariff

3 months historical energy data frozen storage

Measurement: Active kWh (positive and negative),

reactive power, U, I, P, Q, S, PF, F, etc.

Read More

ACR10R-D16TE

Single Phase Energy Meter

For Sungrow, Ginlong inverters, etc.

Read More

ADW200 Series

Multi-channel Energy Meter

5A, 100A, 400A, 600A

Measure 4 channels of 3 phase circuits

Read More

ADL3000-E/C(DTSD1352-C) 3 Phase Meter

For Sungrow, Ginlong(Solis) inverters

2 channels of RS485

Multi-tariff

1DI/1DO

3 channels of temperature measurement

2-31st harmonic

Frozen data on last 48 months, last 90 days

Read More

AGF-AE-D

Single phase 3 wires energy meter

For solar power

Read More

ADW210 Series

Multi-channel Energy Meter

Input current: 5A, 100A, 400A, 600A

Measure 4 channels of 3 phase circuits

Read More

AMC72 3 Phase Energy Meter

Input current: 5A, or 1A

RS485(Modbus-RTU)

2DI/2DO

THDi, THDu

SOE:event record

Measurement: Active kWh (positive and negative),

reactive power, U, I, P, Q, S, PF, F, etc.

Read More

AKH-0.66K-200*80 Split core current transformer

(1000-5000)/5(1)A, 

200*80mm

Accuracy: 0.2

Read More

ADF400L Series

Multi-channel Energy Meter

Measure 12 channels of 3 phase circuits,

or 36 channels of 36 single phase circuits

Input current: 3*1(6)A, 80A

Read More

APM830 Three Phase Energy Meter

Measurement: total electrical measurement,

Pulse output of  energy

Demand data, Event log

Extreme value statistics

Power quality analysis

RS485(Modbus-RTU), 1 Profibus-DP

10DI+4DO, 8AI+4AO

Multi tariff, TF card storage

1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol

Read More

  • Previous:
  • Next:

  • Technical parameters
    Index
     
     
     
    Input
    Voltage input range
    DC 0-1000V, See the physical wiring diagram
     
    Current input
    Shunt:0-75mV;
    Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on.
    Overload
    1.2 times rated (continuous); 2 times rated/1 second;
    Power consumption
    Voltage: ≤0.2VA, current ≤0.1VA
    Accuracy class
    Class 1
     
     
     
     
     
    Function
    Display
    8-bit segment LCD screen (LCD)
    Communication Interface
    RS485(two channels of RS485 can be chosed)
    Communication protocol
    Modbus-RTU,DL/T 645-2007
    Switch output
    2 Relay outputs, 2A/30VDC or 2A/250VAC
    Switch input
    2 dry contact inputs
     
    Pulse output
    A second pulse output, an energy pulse output
    See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH
     
    Power Supply
    Voltage range
    AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
    Power consumption
    ≤ 3W
     
    Power frequency withstand voltage
    Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min
    Power supply // Relay output // Voltage input // Current input 3kV/1min
    Pulse output // Communication interface // Switch input 2kV/1min
    Impulse withstand voltage
    ±6KV
    Insulation resistance
    ≥ 40M Ω
    Average barrier-free working hours
    ≥50000h
     
     
    Environment
     
    Temperature
    Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+80℃
    Humidity
    ≤93%RH, no condensation, no corrosive gas
    Altitude
    ≤2500m

    1. who are we?
    We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc.
    Our Products: AC/DC electricity meters, current transformers, hall sensors, transducers, gateways, Motor protectors, wireless temperature monitoring, residual current relays, medical IT, IOT platform, other energy management systems, etc.

    As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.

    2. What is your website?
    www.acrel.sg

    3. how can we guarantee quality?
    Always a pre-production sample before mass production;
    Always final Inspection before shipment;

    4.what can you buy from us?
    AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.

    5. why should you buy from us not from other suppliers?
    147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.

    6. what services can we provide?
    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc.
    Accepted Payment Currency: USD, EUR, RMB, etc.
    Accepted Payment Type: T/T, L/C, etc.
    Language Spoken:English, Spanish, Chinese, etc.

     

  • Write your message here and send it to us