DJSF1352-RN DC Energy Meter for Solar Power
DC Energy Meter
Measures 2 channels of DC energy and bidirectional DC energy, 2 RS485(Modbus-RTU) , 2DI/2DO, Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V), etc.
DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.
Note: when dual DC input(D)function is selected,if Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided,the built-in power supply of elecctric meter can be used.
Other Applications:
● Communication: RS485(Modbus-RTU)
● 2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;
Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: DIN 35mm
● Built-in Bipolar Power Source:
Power Supply for Hall Effect CT
Range: DC -12V ~ DC +12V
Connected via hall sensor
Connected via shunt
Unit: mm
IOT Platform
All electricity data can be transmitted to the IOT platform
Prepayment management
Electricity data analysis
Alarming
Issue report
ADL200/C Single Phase Meter
RS485(Modbus-RTU)
Multi-tariff
3 months historical energy data frozen storage
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADW200 Series
Multi-channel Energy Meter
5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
ADL3000-E/C(DTSD1352-C) 3 Phase Meter
For Sungrow, Ginlong(Solis) inverters
2 channels of RS485
Multi-tariff
1DI/1DO
3 channels of temperature measurement
2-31st harmonic
Frozen data on last 48 months, last 90 days
ADW210 Series
Multi-channel Energy Meter
Input current: 5A, 100A, 400A, 600A
Measure 4 channels of 3 phase circuits
AMC72 3 Phase Energy Meter
Input current: 5A, or 1A
RS485(Modbus-RTU)
2DI/2DO
THDi, THDu
SOE:event record
Measurement: Active kWh (positive and negative),
reactive power, U, I, P, Q, S, PF, F, etc.
ADF400L Series
Multi-channel Energy Meter
Measure 12 channels of 3 phase circuits,
or 36 channels of 36 single phase circuits
Input current: 3*1(6)A, 80A
APM830 Three Phase Energy Meter
Measurement: total electrical measurement,
Pulse output of energy
Demand data, Event log
Extreme value statistics
Power quality analysis
RS485(Modbus-RTU), 1 Profibus-DP
10DI+4DO, 8AI+4AO
Multi tariff, TF card storage
1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
Technical parameters
|
Index
|
|
Input
|
Voltage input range
|
DC 0-1000V, See the physical wiring diagram
|
Current input
|
Shunt:0-75mV;
Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. |
|
Overload
|
1.2 times rated (continuous); 2 times rated/1 second;
|
|
Power consumption
|
Voltage: ≤0.2VA, current ≤0.1VA
|
|
Accuracy class
|
Class 1
|
|
Function
|
Display
|
8-bit segment LCD screen (LCD)
|
Communication Interface
|
RS485(two channels of RS485 can be chosed)
|
|
Communication protocol
|
Modbus-RTU,DL/T 645-2007
|
|
Switch output
|
2 Relay outputs, 2A/30VDC or 2A/250VAC
|
|
Switch input
|
2 dry contact inputs
|
|
Pulse output
|
A second pulse output, an energy pulse output
|
|
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH
|
||
Power Supply
|
Voltage range
|
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
|
Power consumption
|
≤ 3W
|
|
Power frequency withstand voltage
|
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min
Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch input 2kV/1min |
|
Impulse withstand voltage
|
±6KV
|
|
Insulation resistance
|
≥ 40M Ω
|
|
Average barrier-free working hours
|
≥50000h
|
|
Environment
|
Temperature
|
Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+80℃
|
Humidity
|
≤93%RH, no condensation, no corrosive gas
|
|
Altitude
|
≤2500m
|
1. who are we?
We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc.
Our Products: AC/DC electricity meters, current transformers, hall sensors, transducers, gateways, Motor protectors, wireless temperature monitoring, residual current relays, medical IT, IOT platform, other energy management systems, etc.
As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.
2. What is your website?
www.acrel.sg
3. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
4.what can you buy from us?
AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.
5. why should you buy from us not from other suppliers?
147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.
6. what services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc.
Accepted Payment Currency: USD, EUR, RMB, etc.
Accepted Payment Type: T/T, L/C, etc.
Language Spoken:English, Spanish, Chinese, etc.