Medical Isolation Power Supply Cabinet

● For distribution system in group 2 medical location
● Using Q235A High Quality Cold Rolled Steel Plate
● Louver type heat dissipation fan
● Various installation types
● IP31


Product Detail

Products Selection

FAQ

Certificate

General

Medical isolation power distribution cabinet is a cabinet with a local IT sytems designed for medical group II power supply requirements. Insulation monitoring device installed in IT system monitor insulation condition of the system. Each output circuit has circuit breaker with short circuit protection function,the output circuit in TN-S system has a circuit breaker with leakage protection. Products are divided into GGF-O series three-phase isolated power cabinet,and GGF-I series single-phase isolated power supply cabinet. According to the number of input voltage phases,these products can satisfy the power safety and reliability requirements of various operating room and intersive care unit,and the products meet GB16895.24-2005/iec60364-7-710:2001 and GB7251.12-2013/IEC 61439-2:2011. 

Specification

Technical Parameters

GGF-IXG

GGF-IXQ

GGF-IXF

GGF-OXG

GGF-OXQ

GGF-OXF

Rated voltage

220VAC

380V/220V AC

Rated Capacity

3.15/5/6.3/8/10

--

3.15/5/6.3/8/10

--

Rated frequency

50/60Hz

Distribution circuit

IT system4/5 channels AC220V

IT system8 channels AC220V

--

TN-S system1AC380V,8AC220V

IP Level

IP31

IP34D

IP31

IP34D

Installation

Grounded

Embedded

Grounded

Embedded

Inlet and Outlet Line

Bottom Inlet and output

Both bottom and top have access lines

Bottom Inlet and output

Both bottom and top have access lines

Communication

RS485 interfaceModbus-RTU protocol

 

Application video

https://youtu.be/FC-17bv8F34

Dimension  

QQ截图20150807102746_副本

Diagram

165749px

GGF-I8 Isolation power cabinet system diagram

Projects

1. Acrel Medical Isolated Power Supply System in Luanda General Hospital, Angola

2. ACREL Hospital Isolated Power Supply Application in Malaysia

IT PROJECTS

  • Previous:
  • Next:

  •  Acrel Medical IT System Insulation Monitoring and Fault Location Products Selection Table V1.0

    Note“□”is optional“—”is not optional“■”is selection.

     

    Medical Single Phase Isolation Transformer

    AITR-3150

    AITR-5000

    AITR-6300

    AITR-8000

    AITR-10000

    Capacity

    3150VA

    5000VA

    6300VA

    8000VA

    10000VA

     

    Insulation monitor

    AIM-M10

    AIM-M100

    AIM-M200

     

     

    Power supply

    AC220±10%

     

     

     

     

    AC85~265V

    DC100-300V

     

     

     

     

    DC24V

     

     

     

     

    Communication

    RS485

     

     

     

     

    RS485+RS485

     

     

     

     

    RS485+CAN

     

     

     

     

    Output

    DO1(over temperature)

     

     

     

     

    DO1(over temperature)

    DO2(alarm)

     

     

     

     

    DO1(over temperature)

    DO2(alarm) DO3(programmable)

     

     

     

     

     

    1 channel DC24V

     

     

     

     

    Support fault location

    No

     

     

     

    Yes

     

     

     

     

    Power supply

    ACLP10-24

    HDR-60-24

     

     

     

    Insulation monitor

    AIM-M100

     

     

     

     

    AIM-M200

     

     

     

     

    Alarm indicator

    AID10

    AID120

    AID150

    AID200

    Display

    LED

     

     

    LCD

     

     

    Multi-machine display

    No

     

     

    Yes

     

     

     

    Current transformer

    AKH-0.66P26

     

     

     

     

     

     

     

     

     

    Test signal generator

    ASG150

     

     

     

     

    Support fault location

     

    No

     

     

     

     

    Yes

     

     

     

     

    Fault locator

    AIL150-4

    AIL150-8

     

     

     

    Support fault location

     

    No

     

     

     

    Yes

     

     

     

    Locate number of channels

     

    <=4

     

     

     

     

    >4;  <8

     

     

     

     

    >8 Note 1

     

     

     

    Other

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Note: 1. More than 8 channels can be freely combined, and the maximum support 24 locate channels.

                

    Ordering example

    Example 1: Isolation transformer 8kVA; AC220V; Insulation monitoring; Operating room LCD display; DO output programmable,According to the selection tableconfirm the model isAITR-8000AIM-M100ACLP10-24AKH-0.66P26AID150

    Example 2Isolation transformer 10kVA; Insulation monitoring; Fault location; ICU LCD display; DO outputLocate 12 loops

    According to the selection tableconfirm the model isAITR-10000AIM-M200HDR-60-24AKH-0.66P26AID150ASG150AIL150-4AIL150-8

     

    Q: Are you trading company or manufacturer ?

    A: We are a manufacturer in Shanghai,China. Our factory is in Wuxi city, Jiangsu province.

    Q: How long is your delivery time?

    A: Generally it is 3-5 days if the goods are in stock. Or it is 10-15 days if the goods are not in stock, it is according to quantity.

    Q: Do you provide samples ?  is it free or extra ?

    A: Yes,we can provide the sample for low price. If you place the order ,all or part of the sample charge will be deducted from the goods.

    Q: How long can you send your quotation to us ?

    A: After got all the detailed information,we will quote within 1 working days.

    QWhat is your terms of payment ?

    A: Payment=1000USD,100% in advance. Payment 1000USD,30% Total contract amount in advance, balance before shipment.

    If you have another question,pls feel free to contact us.

    CE_副本

    Write your message here and send it to us