BA20-AI AC Current Transducer Measuring 0-200A
● Model: BA20-AI/I, BA20-AI/V
● Aperture: 20mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA10-AI AC Current Transducer Measuring 0-50A
● Model: BA10-AI/I, BA10-AI/V
● Aperture: 9.5mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA Series AC Straight Through Current Transducer
● Model: BA05,BA10,BA20,BA50
● Aperture: 5mm,10mm,20mm,50mm
● Input: AC0-10A,AC0-50A,AC0-200A,AC0600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA50-AI AC Current Transducer Measuring 0-600A
● Model: BA50-AI/I, BA50-AI/V
● Aperture: 50mm
● Input: AC0-(60-600)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BD-AV Single Phase AC Voltage Transducer
● Model:BD-AV
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD series Electrical Power/Energy Transducer
● Model: BD-3E/BD-4E
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
AKH-0.66/TD-50III Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~800A AC● Primary Current Input: 20mA, 5A● Rated Frequency: 50~60Hz● Installtion: installed on busbar● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
AKH-0.66/TD-60 Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~1000A AC● Primary Current Input: 20mA, 50mA● Rated Frequency: 50~60Hz● Installtion: installed on wires● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
BM200-DI series Single or Dual Input Current Isolated Safety Barrier
● Model: BM200-DI/I
● Input: 0~20mA /4~20mA
● Output: 0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω
● Powered 20~35V DC
● 35mm Din rail installation
-
AKH-0.66/K-50 Series Current Transformer For Cable
● Split core current transformer
● Accuracy: class 0.5
● Suitable for electricity renovation project
-
AKH-0.66/I series current transformer
● Current transformer for measurement
● Suitable for cables or copper bus
● Used with energy meters or relays
Standards
IEC/EN61869-1, IEC/EN61869-2 -
BA50L AC Leakage Current Transducer
● Model: BA50L-AI/I, BA50L-AI/V
● Input: AC0-1A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
AKH-0.66/K series split core current transformer
● Split core current transformer
● Easy to install without power off
● Suitable for electricity renovation project