● Suitable for motors with rated voltage of AC380V/660V;
● Optional leakage protection, RS485 communication, analog output, etc.
● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 4 channels DO output.
● Type: AMC48L-AI,AMC72L-AI,AMC96L-AI ● AC current: AC1A or 5A ● 1 x RS485 with programmable Modbus RTU; ● Optional function: Alarm, Analog output, DI/DO and communication; ● Economic programmable meter; ● Accuracy: Class 0.5
● Measure largest 36 circuits single-phase or 12 circuits three-phase ● AC 3 * 220 / 380V ● 3×1(6)A,3×10(80)A ● RS485(MODBUS-RTU) ● Set parameters ● LCD display ● kWh Class 0.5 ● DIN 35 mm
● True RMS Measurements ● THD with 63rd Harmonics ● K-Factor and Crest Factor ● Unbalance & Phase Angles ● Demands and Multi-Tariff energy ● Max/Min Log with Timestamp
● Model: BD-DV ● DC current input:DC0-10V,0-75mV,0-300V ● Overload: 1.2 times of rated value ● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA ● Power supply: AC85-265V/DC24V/DC48V
● Type: AMC96L-E4/KC ● Size: 96*96mm ● True RMS Measurements ● THD with 2-31st Harmonics ● Max/Min Log with Timestamp ● Internal Optional 4DI&2DO or 2DI&2DO&2AO ● Standard one Energy Pulse Output
● Rated current input:10mA-2A
● Rated output: 5V
● Power supply: ±15V
● Rated current input:DC0-(50-4000)A
● Rated output: 5V/4-20mA/50mA
● Power supply: ±15V / 12V / 24V
● Rated current input:0-(100-2000)A
● Rated output: 50mA/100mA/200mA/400mA
● Aperture: 20mm/40mm/60mm/etc
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V ● 3×1(6)A,3×10(80)A, 3×20(100)A ● U、I、P、Q、S、PF、kWh、kvarh ● RS485(MODBUS-RTU) ● LCD display ● Frozen data ● 2-31st Harmonics ● kWh Class 0.5S,kVarh Class 2
● Type: AMC48L-AV3,AMC72L-AV3,AMC96L-AV3 ● AC current: AC100V,220V,380V ● 1 x RS485 with programmable Modbus RTU; ● Optional function: Alarm, Analog output, DI/DO and communication; ● Economic programmable meter; ● Accuracy: Class 0.5
● Model: BA20(II)-AI,BA50(II)AI ● Aperture: 20mm,50mm ● Input: AC0-600A ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA ● Overload: 1.2 times of rated value ● Power supply: DC12V/DC24V
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V ● 3×1(6)A, 3×20(100)A ● U、I、P、Q、S、PF、kWh、kvarh ● RS485(MODBUS-RTU) ● LCD display ● Frozen data ● 2-31st Harmonics ● kWh Class 0.5S,kVarh Class 2
● Designed specifically for the power supply management of server in the data center
● Including 2 incoming line circuit and 36 outgoing line circuit
● U, I, P, Q, S, PF, kWh, kvarh
● Optional 2nd-15th harmonic
● Current transformer for measurement
● Suitable for cables or busbar
● Used with energy meters or relays
● 30I, 40I Optional Din Rail Mounted
● Temperature and humidity measuring & controlling ● LED display ● Accuracy: Temperature ±1℃ Humidity ±5%RH ● Power supply: AC 85-265V, DC 100-350V
LTE-FDD B1 B2 B3 B4 B5 B7 B8 B12 B13 B18 B19 B20 B25 B26 B28
LTE-TDD B38 B39 B40 B41
UMTS B1 B2 B4 B5 B6 B8 B19
GSM B2 B3 B5 B8 LORA 860~935MHz