BA Series Split Current Transducer
● Model: BA20(II)-AI,BA50(II)AI
● Aperture: 20mm,50mm
● Input: AC0-600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
AGF-Mseries Multi channel din rail smart solar string monitor device for pv combiner box
● 4,8,12,16,20 or 24 string measurement with inner hall effect clamps
● pv string current input:DC 0-±20A (built-in hall sensor)
● Input voltage:DC0-1000V
● Accuracy:0.5
● DI(3 external states input,Optocoupler or dry contact)
● Analog input:PT100,DC0-20ma,DC4-20ma or DC0-10V
● Communication:Modbus over RS485
● Auxiliary power supply:DC1000V or DC1500V
-
DC Energy Meter PZ72(L)-DE
● Measure voltage, current, power, forward and reverse power in DC system● Local display● RS485(MODBUS-RTU)● Set parameters● DI/DO, Relay alarm output● Applications:DC panels, solar power, telecommunications base stations, and charging posts -
ARD2 Smart Motor Protector
● Suitable for motors with rated voltage of AC380V/660V;
● Optional leakage protection, RS485 communication, analog output, etc.
● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 4 channels DO output.
-
ACR10R-DXXTE Single Phase Energy Meter With External Split CTs for PV System
● Type:ACR10R-D10TE,ACR10R-D16TE,ACR10R-D24TE,ACR10R-D36TE● Current input:80A,120A,200A,300A● Measurement current、voltage、active power, reactive power, power factor● RS485 communication interface -
AMC**L-AI Single Phase Current Meter
● Type: AMC48L-AI,AMC72L-AI,AMC96L-AI
● AC current: AC1A or 5A
● 1 x RS485 with programmable Modbus RTU;
● Optional function: Alarm, Analog output, DI/DO and communication;
● Economic programmable meter;
● Accuracy: Class 0.5 -
ADF400L Multi-circuits Energy Meter
● Measure largest 36 circuits single-phase
or 12 circuits three-phase
● AC 3 * 220 / 380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm -
APM Series of Multifunction Energy Meter
● True RMS Measurements
● THD with 63rd Harmonics
● K-Factor and Crest Factor
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp -
BD-DV DC Voltage Transducer
● Model: BD-DV
● DC current input:DC0-10V,0-75mV,0-300V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
AMC96L-E4/KC Programmable Energy Meter
● Type: AMC96L-E4/KC
● Size: 96*96mm
● True RMS Measurements
● THD with 2-31st Harmonics
● Max/Min Log with Timestamp
● Internal Optional 4DI&2DO or 2DI&2DO&2AO
● Standard one Energy Pulse Output -
AHLC-LTA DC leakage current sensor
● Rated current input:10mA-2A
● Rated output: 5V
● Power supply: ±15V
-
ACTDS-DV series DC voltage hall sensor
● Rated current input:DC0-(50-4000)A
● Rated output: 5V/4-20mA/50mA
● Power supply: ±15V / 12V / 24V
-
Closed Loop Hall Current Sensor
● Rated current input:0-(100-2000)A
● Rated output: 50mA/100mA/200mA/400mA
● Aperture: 20mm/40mm/60mm/etc
● Power supply: ±15V / 12V / 24V
-
DTSD1352 Three Phase Din Rail Energy Meter
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A,3×10(80)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
AMC**L-AV3 Three Phase Voltage Meter
● Type: AMC48L-AV3,AMC72L-AV3,AMC96L-AV3
● AC current: AC100V,220V,380V
● 1 x RS485 with programmable Modbus RTU;
● Optional function: Alarm, Analog output, DI/DO and communication;
● Economic programmable meter;
● Accuracy: Class 0.5 -
ADF400 Series Multi-circuits Energy Meter
● Measure largest 36 circuits single-phase
or 12 circuits three-phase
● AC 3 * 220 / 380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm -
BA Series Intelligent Current Sensor
● Model: BA20(II)-AI,BA50(II)AI
● Aperture: 20mm,50mm
● Input: AC0-600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
AMC96L-E4/KC 3 Phase Panel Energy Meter
● Type: AMC96L-E4/KC
● Size: 96*96mm
● True RMS Measurements
● THD with 2-31st Harmonics
● Max/Min Log with Timestamp
● Internal Optional 4DI&2DO or 2DI&2DO&2AO
● Standard one Energy Pulse Output -
ADL3000-E/CT Three Phase Din Rail Energy Meter with 3 split CTs
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
AMC16MA Data Center Monitor Device
● Designed specifically for the power supply management of server in the data center
● Including 2 incoming line circuit and 36 outgoing line circuit
● U, I, P, Q, S, PF, kWh, kvarh
● Optional 2nd-15th harmonic