Open Hall Current Sensor
● Rated current input:0-(50-5000)A
● Rated output: 5v / 4v / 4-20mA
● Aperture: 20mm/40mm/55mm/etc
● Power supply: ±15V / 12V / 24V
-
BA20-AI AC Current Transducer Measuring 0-200A
● Model: BA20-AI/I, BA20-AI/V
● Aperture: 20mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA10-AI AC Current Transducer Measuring 0-50A
● Model: BA10-AI/I, BA10-AI/V
● Aperture: 9.5mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA Series AC Straight Through Current Transducer
● Model: BA05,BA10,BA20,BA50
● Aperture: 5mm,10mm,20mm,50mm
● Input: AC0-10A,AC0-50A,AC0-200A,AC0600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA50-AI AC Current Transducer Measuring 0-600A
● Model: BA50-AI/I, BA50-AI/V
● Aperture: 50mm
● Input: AC0-(60-600)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BD-AV Single Phase AC Voltage Transducer
● Model:BD-AV
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD series Electrical Power/Energy Transducer
● Model: BD-3E/BD-4E
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
ADW210 Series Multi-Loop Power Meter
● Mearsure Up to 4 circuit 3 phase
● LCD display
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADW200 Series Multi Channel Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication) -
ADW210 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
AKH-0.66/TD-50III Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~800A AC● Primary Current Input: 20mA, 5A● Rated Frequency: 50~60Hz● Installtion: installed on busbar● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
AKH-0.66/TD-60 Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~1000A AC● Primary Current Input: 20mA, 50mA● Rated Frequency: 50~60Hz● Installtion: installed on wires● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
ADL3000-E/C(DTSD1352-C) 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: CE; IEC -
ADL200/C Single Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measurement: Active kWh (positive and negative), reactive power, U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), Infrared communication
● Multi tariff
● Data Record: 3 months historical energy data frozen storage(optional)
● Accuracy:Class 1.0
● Pulse output: Active energy pulse output
● Display: 8 digits display U, I, P, Q, PF, kWh and other energy consumption
● 3 keys to set parameters, such as code, address, baud rate, multi-tariff and communication protocol
● Rated voltage: AC 220V, 230V
● Rated current: 10(80)A, measure 0.01A-80A
● Standard&Certificate: MID, CE, IEC -
DJSF1352-RN DC Energy Meter for Solar Power
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC -
ADW210 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW200 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW220 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU), Lora
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW210 series network power meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), I,U, kW,kvar, kWh, kvarh,Hz,cosø, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: Modbus-RTU protocol, DL/T 645-2007 statute
● Harmonic content of voltage and current(2-63 times)
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
Acrel AHE100 Wireless Temperature & Humidity Monitoring Sensor for Cable/Busbar Temperature Monitoring
● Wireless transmit,470MHz;
● Wireless transmission distance, 500 m;
● Built-in battery powered;
● Widely temperature measuring range, -30℃~+85℃.
● Widely humidity measuring range, 0-100% RH;
● Sampling frequency: 25s;
● Transmitting frequency: 5 Min;
● Standard & Certificate: IEC, CE;