Energy Consumption Monitoring Solution for Base Station

Application

 

It is necessary to measure and monitor electrical parameters and measure energy in AC side of tower base station such as state grid, diesel, air conditioner, lighting, power supply and so on. In DC side, it is necessary to monitor electrical parameters and measure energy such as base station communication device, battery and other devices working under -48V power supply. The data can be real-time uploaded by RS485.

Structure

1
2
3

Main Functions

1. Measurement:multi circuits voltage,current,power,energy and other electrical parameters.

2. Communication:RS485 Modbus-RTU,NB or 4G

3. Certificate:With CE and IEC 

4. Accuracy:0.5s or 1

Product Selection

1) AMC96L-E4/KC Multifunction Meter

● True RMS Measurements

● THD with 2-31st Harmonics

● Max/Min Log with Timestamp

● Internal Optional 4DI&2DO or 2DI&2DO&2AO

● Standard one Energy Pulse Output

2) AMC16-DETT Base Station DC Energy Meter

 

●DC rated voltage: 1 channel: -48VDC
●Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
●RS485(MODBUS-RTU)
●LED display
●DIN 35 mm

3) ADW200 Series Multi-Loop Power Meter

 

ADW200 series multi-loop power meter is mainly used for the measurement of all electric parameters of three-phase circuit. Colleagues can select the current input of the maximum four circuits.

4) ADL400 Din Rail Energy Meter

● AC3*100V,3*380V,3*57.7/100V,3*220/380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm

5) ADL3000-E Three Phase Multi-function Energy Meter

● AC 3×220/380V,3×380V,3×57.7/100V,3×100V 
● 3×1(6)A,3×10(80)A
●  U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data 
● 2-31st  Harmonics
● kWh Class 0.5S,kVarh Class 2 

 

6) ADW350 Wireless Energy Meter

● DIN 35 mm

● 3 circuits DC input or 1 circuit 3 phase AC input

● Measurement: voltage, current, power, energy and other parameters

● Communication: NB or 4G

7) DJSF1352-RN rail-mounted DC power meter

●RS485 communication interface
●Supports Modbus-RTU protocol
●Relay alarm output and digital input function
●Set the ratio, alarm, and communication through the meter panel keys according to different requirements
●Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power

8) AHKC-E Hall sensor

 

AC, DC, pulse and other complex current


Post time: Dec-23-2020